ECG (main): Difference between revisions

(adding the paper speed.)
No edit summary
Line 1: Line 1:
==Measurement==
==Measurement==
[[File:Grid.png|thumb]]
[[File:Grid.png|thumb]]
''All these measures are valid for the standard paper speed of 25 mm/Sec''
*1 small box = 1mm = 0.04 sec = 40 miliseconds
*1 small box = 1mm = 0.04 sec = 40 miliseconds
*5 small boxes = 1 big box = 5mm = 0.2 sec = 200 miliseconds
*5 small boxes = 1 big box = 5mm = 0.2 sec = 200 miliseconds
Line 23: Line 24:
| N/A
| N/A
|}
|}
All these measures are valid for the paper speed of 25 mm/Sec.


==Primary Analysis==
==Primary Analysis==

Revision as of 10:40, 3 November 2016

Measurement

Grid.png

All these measures are valid for the standard paper speed of 25 mm/Sec

  • 1 small box = 1mm = 0.04 sec = 40 miliseconds
  • 5 small boxes = 1 big box = 5mm = 0.2 sec = 200 miliseconds
  • Standard 12 lead ECG duration = 10 seconds
Interval Time(s) Boxes
PR 0.12 - 0.20 3-5
QRS 0.06 - 0.10 1.5-2.5
QTc <0.44 N/A

Primary Analysis

Segments & Intervals

SinusRhythmLabels.svg

Waves

Hypertrophy/Enlargement

Cardiac Hypertrophy and Enlargement

AV Blocks

AV blocks

Bundle and Fascicular Blocks

See Also

Video

{{#widget:YouTube|id=LCFXZvnW3rg}}

External Links

References