Template:Lung Protective FiO2 and PEEP Scale

Revision as of 19:27, 21 March 2020 by Rossdonaldson1 (talk | contribs) (/* Lung Protective FiO2 and PEEP ScaleThe Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respirat...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Lung Protective FiO2 and PEEP Scale[1][2][3]

FiO2 0.3 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.7 0.8 0.9 0.9 0.9 1.0 1.0 1.0
PEEP 5 5 8 8 10 10 10 12 14 14 14 16 18 20 22 24
  1. The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000;342(18):1301-1308.
  2. Kallet RH, et al. "Respiratory controversies in the critical care setting. Do the NIH ARDS Clinical Trials Network PEEP/FIO2 tables provide the best evidence-based guide to balancing PEEP and FIO2 settings in adults?" Respiratory Care. 2007. 52(4):461-75.
  3. ARDSnet protocol card