Modified positional valsalva

Revision as of 04:46, 21 August 2019 by Rossdonaldson1 (talk | contribs) (→‎External Links)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Background

2015 REVERT Trial

  • Studied modified Valsalva for SVT conversion to normal sinus:[1]
    • Normal Valsalva - 17% resolution
    • Modified Positional Valsalva - 43% resolution
  • No adverse events or costs associated with Modified Positional Valsalva

Modified positional valsalva

Set-up

Screen Shot 2016-08-04 at 6.14.06 PM.png
Screen Shot 2016-08-04 at 5.53.13 PM.png
  • 10ml syringe with plunger
  • Two assistants - one to adjust head of bed and another to raise/lower legs.

Steps

  1. Position patient with legs flat and head of bed to 45°
  2. Have patient attempt to blow out plunger of 10ml syringe (or Valsalva around 40mmHg) for 15 seconds
  3. Quickly reposition patient's head of bed to flat and have the other assistant raise legs to 45° for another 15 seconds
  4. Return head of bed to 45° and continue to monitor for resolution for 1 minute
  5. Repeat if needed

External Links

See Also

References

  1. Appelboam A. et al. Postural modification to the standard Valsalva manoeuvre for emergency treatment of supraventricular tachycardias (REVERT): a randomised controlled trial fulltext