IVC ultrasound
Revision as of 02:56, 31 October 2011 by Rossdonaldson1 (talk | contribs)
Background
- Inferior vena cava ultrasound measurements
- >50% collapse correlates with CVP <8
Measurements
IVC | % Collapse during inspiration^ | CVP |
<1.5cm | >50% | 0-5 |
1.5-2.5cm | >50% | 5-10 |
1.5-2.5cm | <50% | 10-15 |
>2.5cm | Little phasicity | 15-20 |
^Measure ~2cm from IVC/RA junction