IVC ultrasound: Difference between revisions
(Created page with "*Measure ~2cm from IVC/RA junction {| border="1" cellspacing="1" cellpadding="1" style="width: 300px; " |- | IVC | % Collapse during inspiration | CVP |- | <1.5cm | >50% | 0-5 |...") |
No edit summary |
||
Line 1: | Line 1: | ||
{| cellspacing="1" cellpadding="1" border="1" style="width: 300px;" | |||
{| | |||
|- | |- | ||
| IVC | | '''IVC''' | ||
| % Collapse during inspiration | | ''' % Collapse during inspiration^''' | ||
| CVP | | '''CVP''' | ||
|- | |- | ||
| | | <1.5cm | ||
| | | >50% | ||
| 0-5 | | 0-5 | ||
|- | |- | ||
| 1.5-2.5cm | | 1.5-2.5cm | ||
| | | >50% | ||
| 5-10 | | 5-10 | ||
|- | |- | ||
| 1.5-2.5cm | | 1.5-2.5cm | ||
| | | <50% | ||
| 10-15 | | 10-15 | ||
|- | |- | ||
| | | >2.5cm | ||
| Little phasicity | | Little phasicity | ||
| 15-20 | | 15-20 | ||
|} | |} | ||
==See Also== | ^Measure ~2cm from IVC/RA junction | ||
== See Also == | |||
*[[Ultrasound (Main)]] | *[[Ultrasound (Main)]] | ||
[[Category:Cards]] | [[Category:Cards]] [[Category:Rads]] | ||
[[Category:Rads]] |
Revision as of 18:26, 17 July 2011
IVC | % Collapse during inspiration^ | CVP |
<1.5cm | >50% | 0-5 |
1.5-2.5cm | >50% | 5-10 |
1.5-2.5cm | <50% | 10-15 |
>2.5cm | Little phasicity | 15-20 |
^Measure ~2cm from IVC/RA junction