==Background==
 +
*Inferior vena cava ultrasound measurements
 +
*>50% collapse correlates with CVP <8
 +
 +
==Measurements==
 
{| cellspacing="1" cellpadding="1" border="1" style="width: 300px;"
 
{| cellspacing="1" cellpadding="1" border="1" style="width: 300px;"
 
|-
 
|-
Line 23: Line 28:
  
 
^Measure ~2cm from IVC/RA junction  
 
^Measure ~2cm from IVC/RA junction  
 +
  
 
== See Also ==
 
== See Also ==
 
 
*[[Ultrasound (Main)]]
 
*[[Ultrasound (Main)]]
  
 
[[Category:Cards]] [[Category:Rads]]
 
[[Category:Cards]] [[Category:Rads]]

Revision as of 02:56, 31 October 2011

Background

  • Inferior vena cava ultrasound measurements
  • >50% collapse correlates with CVP <8

Measurements

IVC  % Collapse during inspiration^ CVP
<1.5cm >50% 0-5
1.5-2.5cm >50% 5-10
1.5-2.5cm <50% 10-15
>2.5cm Little phasicity 15-20

^Measure ~2cm from IVC/RA junction