==Background==
 
==Background==
*Inferior vena cava ultrasound measurements
+
*Inferior vena cava measurement by ultrasound to estimate volume status
*>50% collapse correlates with CVP < 8
+
*Measure both absolute diameter of IVC and percent collapse during inspiration of spontaneously breathing patients
*Unclear if able to use in intubated patients
+
*can use as a dynamic assessment after intervention (giving fluids)
 +
*Unclear if applicable to intubated patients
  
 
==Technique==
 
==Technique==

Revision as of 22:59, 5 March 2015

Background

  • Inferior vena cava measurement by ultrasound to estimate volume status
  • Measure both absolute diameter of IVC and percent collapse during inspiration of spontaneously breathing patients
  • can use as a dynamic assessment after intervention (giving fluids)
  • Unclear if applicable to intubated patients

Technique

  • Use phased array probe
  • In subxyphoid cardiac view (epigastric), fan probe inferiorly to view the IVC draining into the right atrium
    • may start with subxyphoid view, place right atrium in center of screen and rotate probe 90 degrees clockwise to find IVC
  • In the RUQ, slide the probe posteriorly to view the IVC draining into the right atrium

Measurements

IVC  % Collapse during inspiration^ CVP
<1.5cm >50% 0-5
1.5-2.5cm >50% 5-10
1.5-2.5cm <50% 10-15
>2.5cm Little phasicity 15-20

^Measure ~2cm from IVC/RA junction

  • Can ask patient to sniff or valsalva to evaluate collapse