Extubation: Difference between revisions
Neil.m.young (talk | contribs) (Text replacement - "Pt " to "Patient ") |
Neil.m.young (talk | contribs) (Text replacement - " w/ " to " with ") |
||
Line 24: | Line 24: | ||
***If sat <90%, HR >140, SBP >200, severe anxiety or decreased LOC discontinue attempt | ***If sat <90%, HR >140, SBP >200, severe anxiety or decreased LOC discontinue attempt | ||
*Perform cuff leak test to assess airway patency (not needed for ED extubation for only few hrs per Weingart article) | *Perform cuff leak test to assess airway patency (not needed for ED extubation for only few hrs per Weingart article) | ||
**Predicts post-intubation stridor | **Predicts post-intubation stridor with sensitivity of 56-92%<ref>Ochoa ME, Marín Mdel C, Frutos-Vivar F, Gordo F, Latour-Pérez J, Calvo E, Esteban A. Cuff-leak test for the diagnosis of upper airway obstruction in adults: a systematic review and meta-analysis. Intensive Care Med. 2009 Jul;35(7):1171-9.</ref> | ||
**Cuff leak refers to airflow around ETT | **Cuff leak refers to airflow around ETT with deflated cuff | ||
**Qualatative measurement: deflate and listen for air | **Qualatative measurement: deflate and listen for air with stethoscope | ||
**Quantative measurement: measure difference between inspired TV while on vent and expired TV | **Quantative measurement: measure difference between inspired TV while on vent and expired TV with deflated cuff (avg lowest 3 expired breaths over 6 cycles) | ||
**Positive cuff leak = volumes <110 mL or <12-24% of TV. This indicates decreased space between ETT and airway (laryngeal edema) | **Positive cuff leak = volumes <110 mL or <12-24% of TV. This indicates decreased space between ETT and airway (laryngeal edema) | ||
**If positive test, consider course of steroids and delay extubation | **If positive test, consider course of steroids and delay extubation | ||
==Procedure<ref>Weingart SD, Menaker J, et al. Trauma Patients Can Safely Be Extubated in the Emergency Department. J Emerg Med. 2009 Aug 22.</ref>== | ==Procedure<ref>Weingart SD, Menaker J, et al. Trauma Patients Can Safely Be Extubated in the Emergency Department. J Emerg Med. 2009 Aug 22.</ref>== | ||
#Have nebulizer filled | #Have nebulizer filled with NS attached to a mask | ||
#Sit patient up to at least 45 degrees | #Sit patient up to at least 45 degrees | ||
#Suction ETT | #Suction ETT with bronchial suction catheter | ||
#Suction oropharynx | #Suction oropharynx with Yankeur suction | ||
#Deflate ETT cuff | #Deflate ETT cuff | ||
#Have patient cough; pull the tube during the cough | #Have patient cough; pull the tube during the cough |
Revision as of 03:48, 12 July 2016
Algorithm is for patients who have only been intubated for a few hours
Inclusion
- Plan to extubate in ED after only few hrs[1]
- Resolution of clinical issue requiring intubation
- Sat >95% on FiO2 40%, PEEP 5
- RR <30, SBP >100, HR <130
- Patient not known to be a difficult intubation
Preparation
- Turn off sedatives
- Leave opiods on at a low dose (e.g. fentanyl 50 mcg/hr)
- Allow patient to regain full mental status
- If patient shows signs of discomfort consider giving more pain medication
- Patient should be able to understand respond to commands
Testing for Readiness
- Mental Status[2]
- Ask patient to raise arm and leave in air for 15s
- Ask patient to raise their head off the bed
- Ask patient to cough (they should be able to generate a strong cough)
- Place on pressure support 5; sit patient up to at least 45 degrees
- Observe for 15-30
- If sat <90%, HR >140, SBP >200, severe anxiety or decreased LOC discontinue attempt
- Perform cuff leak test to assess airway patency (not needed for ED extubation for only few hrs per Weingart article)
- Predicts post-intubation stridor with sensitivity of 56-92%[3]
- Cuff leak refers to airflow around ETT with deflated cuff
- Qualatative measurement: deflate and listen for air with stethoscope
- Quantative measurement: measure difference between inspired TV while on vent and expired TV with deflated cuff (avg lowest 3 expired breaths over 6 cycles)
- Positive cuff leak = volumes <110 mL or <12-24% of TV. This indicates decreased space between ETT and airway (laryngeal edema)
- If positive test, consider course of steroids and delay extubation
Procedure[4]
- Have nebulizer filled with NS attached to a mask
- Sit patient up to at least 45 degrees
- Suction ETT with bronchial suction catheter
- Suction oropharynx with Yankeur suction
- Deflate ETT cuff
- Have patient cough; pull the tube during the cough
- Suction the oropharynx again
- Encourage the patient to keep coughing up any secretions
- Place nebulizer on patient at 4-6 L/min
After Extubation
- Monitor closely for at least 60min
- If patient develops resp distress, non-invasive ventilation will often be sufficient
See Also
Mechanical Ventilation Pages
- Noninvasive ventilation
- Intubation
- Mechanical ventilation (main)
- Miscellaneous
References
- ↑ Weingart SD, Menaker J, et al. Trauma Patients Can Safely Be Extubated in the Emergency Department. J Emerg Med. 2009 Aug 22.
- ↑ Weingart SD, Menaker J, et al. Trauma Patients Can Safely Be Extubated in the Emergency Department. J Emerg Med. 2009 Aug 22.
- ↑ Ochoa ME, Marín Mdel C, Frutos-Vivar F, Gordo F, Latour-Pérez J, Calvo E, Esteban A. Cuff-leak test for the diagnosis of upper airway obstruction in adults: a systematic review and meta-analysis. Intensive Care Med. 2009 Jul;35(7):1171-9.
- ↑ Weingart SD, Menaker J, et al. Trauma Patients Can Safely Be Extubated in the Emergency Department. J Emerg Med. 2009 Aug 22.