Template:COVID-19 intubation: Difference between revisions

Line 2: Line 2:
'''[[Prevention_of_COVID-19_transmission_in_the_healthcare_setting#Aerosol-Generating_Procedures|Aerosol-generating procedure: see this link for PPE recommendations and related precautions]]'''
'''[[Prevention_of_COVID-19_transmission_in_the_healthcare_setting#Aerosol-Generating_Procedures|Aerosol-generating procedure: see this link for PPE recommendations and related precautions]]'''
*Use checklist if available (see example: [[File:Harbor COVID Airway Management v3-16-20.pdf]])
*Use checklist if available (see example: [[File:Harbor COVID Airway Management v3-16-20.pdf]])
*Consider use of [https://vimeo.com/401646409/c102371aee?fbclid=IwAR1KX3BKhXNBfGuz6hCPfVkqnlEiQiphT9exMaASQxVTTAVL5ItLnbbGA54 Aerolsol Box], if available
* Use [[BVM]] with viral filter or avoid BVM altogether, if possible
* Use [[BVM]] with viral filter or avoid BVM altogether, if possible
* Use [[RSI]] to prevent coughing gagging; consider higher dosing of paralytics.
* Use [[RSI]] to prevent coughing gagging; consider higher dosing of paralytics.
* Most experienced provider should perform intubation
* Most experienced provider should perform intubation
*Use video laryngoscopy to keep provider face further away from patient (afterwards, clean with grey wipes, observe 3 min wet time)
*Use video laryngoscopy to keep provider face further away from patient (afterwards, clean with grey wipes, observe 3 min wet time)

Revision as of 17:36, 31 March 2020

Intubation of Potential COVID-19 Patients

Aerosol-generating procedure: see this link for PPE recommendations and related precautions

  • Use checklist if available (see example: File:Harbor COVID Airway Management v3-16-20.pdf)
  • Consider use of Aerolsol Box, if available
  • Use BVM with viral filter or avoid BVM altogether, if possible
  • Use RSI to prevent coughing gagging; consider higher dosing of paralytics.
  • Most experienced provider should perform intubation
  • Use video laryngoscopy to keep provider face further away from patient (afterwards, clean with grey wipes, observe 3 min wet time)