Revision as of 02:35, 12 October 2018
Indications
- Failed airway in adults or children
- Preferred method of rescue airway in infants and children (cutoff 5-12 years of age, depending on sourceCite error: Invalid
<ref>tag; invalid names, e.g. too many)
- Preferred method of rescue airway in infants and children (cutoff 5-12 years of age, depending on sourceCite error: Invalid
- Temporizing measure until definitive airway management
- Obstruction above the level of the cricothryoid membrane
Contraindications
When used as a rescue airway, no absolute contraindications.
- Relative Contraindications
- Inability to identify landmarks
- Tracheal transection or severe trauma
- Underlying tumor, abscess/infection, or other known abnormality
Equipment
- Provodone iodine
- Sterile drapes, gloves, gown, gauze
- 12-14 G angiocath
- 3mL syringe x 2
- Adapter to 7-0 ETT or adapter to 3-0 ETT
- BVM appropriate for size of patient
- Can also use jet vet ventilation setup in adults
- High flow O2 source, 50 PSI
- O2 tubing
- Valve-3 way stop cock or cut holes in O2 tubing
- Depending on O2 source, calculate time valve must be open for tidal volume
- BVM setup does not allow adequate exhalation in adults
- Can also use jet vet ventilation setup in adults
Procedure
- Prep and drape
- Locate cricothyroid membrane
- Pierce membrane with angiocath directed 30-45 deg caudal
- Attach 3mL syringe with saline, aspirate as you enter
- Advance until air is aspirated in syringe
- Advance catheter over needle, hub to skin
- Remove needle
- Attach 3-0 ETT adapter direction to angiocath (best option)
- OR attach 3 mL syringe to catheter, then attach 7-0 ETT adapter to syringe
- OR attach 10 mL syringe to catheter, then insert actual 7-0 ETT (works best with cut down ETT) into syringe and blow up balloon so that ETT does not move
- Attach BVM to ETT adapter
- Secure system
- Ventilate with BVM or high flow O2 setup
- OBTAIN DEFINITIVE AIRWAY
- Should be used for < 45 minutes
Complications
- Hemorrhage
- Infection
- Tracheal stenosis
- Subcutaneous emphysema
- Posterior tracheal perforation