High frequency oscillation ventilation: Difference between revisions

Line 44: Line 44:


===See Also===
===See Also===
[http://lifeinthefastlane.com/ccc/high-frequency-oscillation-ventilation-hfov/ Life in the Fast Lane] - for an excellent review and tutorial
[http://lifeinthefastlane.com/ccc/high-frequency-oscillation-ventilation-hfov/ Life in the Fast Lane] - for an excellent review and tutorial<br />
[http://www.nejm.org/doi/full/10.1056/NEJMoa1215554#t=article Oscillate]
 
[http://www.nejm.org/doi/full/10.1056/NEJMoa1215554#t=article Oscillate]<br />
 
[http://www.nejm.org/doi/full/10.1056/NEJMoa1215716#t=article OSCAR]
[http://www.nejm.org/doi/full/10.1056/NEJMoa1215716#t=article OSCAR]

Revision as of 19:18, 22 June 2016

Background

  • High Frequency Oscillation Ventilation (HFOV) is an alternative method for mechanical ventilation in difficult to oxygenate in critically ill ARDS patients.
  • Studied in patients with PaO2/FiO2 < 200
  • Goal is to maintain alveolar recruitment for adequate gas exchange and decrease lung injury/atelectrauma
    • Low tidal volumes based around mean airway pressures to keep alveoli open
    • Delivered at high frequency
  • Pros
    • Limits VILI
    • May improve oxygenation when ECMO not available
  • Cons
    • No difference or likely to cause harm in adult ARDS patients
    • Requires heavy sedation
    • Increase mean airway pressures may result in more hemodynamic instability

Procedure

Example protocol from Oscillate trial[1]

  • Set FiO2 at 100%
  • Recruitment maneuver of 40 cmH2O PEEP for 40 seconds
  • I:E time of 1:2
  • Initiate high frequency ventilation -> 3-15 Hz
  • VT minimized to keep pH >7.25
    • Goal of 1-4 ml/Kg
  • Maintain mean airway pressure of 30 cmH2O with pressure adjusted to maintain a PaO2 of 55-80 mmHg
  • Reversion to standard ventilation of mean airway pressure was ≤24 cmH2O for 12 hours or anytime when ≤20 cmH2O
  • Re-initiation of HFOV if FIO2 >0.4 or PEEP >14 cmH2O for >1 hour in the subsequent 48 hours

Targets

  • pH>7.25
  • SpO2 >88% or PaO2 >55mmHg

Oxygenation altered by:

  • FiO2
  • Mean airway pressures

Ventilation altered by:

  • Frequency
    • Decrease frequency to increase TV and ventilation
  • Inspiratory time
  • Amplitude of oscillations

See Also

Life in the Fast Lane - for an excellent review and tutorial

Oscillate

OSCAR

  1. Fergusson N, Cook D, Guyatt G. High-frequency Oscillation in Early Acute Respiratory Distress Syndrome. NEJM 2013; 368:795-805