MR Contraindications[1]

Cardiovascular Devices

Device MR Category Comments
Coronary artery stents Most MR Safe (some MR Conditional) Check individual type
Peripheral vascular stents Most MR Safe (some MR Conditional) Check individual type
Aortic stent grafts Most MR Safe Zenith AAA and TAA endovascular grafts (Cook) = MR Conditional
Mechanical cardiac valves (prosthetic heart valves and annuloplasty rings ) Most MR Safe (some MR Conditional)
Sternal wires Generally considered MR safe
Cardiac closure and occluder devices Most MR Safe (some MR Conditional)
IVC filters Most MR Safe (some MR Conditional) Weakly ferromagnetic devices [e.g. Gianturco bird nest IVC filter (Cook), stainless steel Greenfield vena cava filter (Boston Scientific)]: after six weeks as long as no reason to suspect improper positioning or movement
Embolization coils Most MR Safe (some MR Conditional)
Loop recorder (Event monitor) MR Conditional? Stored data may be affected
Hemodynamic monitoring and temporary pacing devices MR Unsafe
Pulmonary artery hemodynamic monitoring/thermodilution catheters (Swan-Ganz catheter and similar catheters ) MR Unsafe (unless otherwise specified)
Temporary pacemaker (external pulse generators or temporary pacing leads) MR Unsafe
Permanent pacemakers and implantable ICDs Strong relative contraindication vs. MR Unsafe Absolute contraindication: pacemakers or ICDs with known lead fractures
Retained transvenous pacemaker and defibrillator leads Strong relative contraindication vs. MR Unsafe Approached same as those with pacemakers or ICDs (see above)
Hemodynamic support devices (intraaortic balloon pump and ventricular assist devices) MR Unsafe

Permanent pacemakers and implantable ICDs

  • Only if no alternative diagnostic test is available and the potential benefit to the patient clearly outweighs the potential risks
  • If performed, the pacemaker/ICD should be interrogated before and after the procedure
  • Risks:
    • pacemaker/ICD dysfunction
    • pacemaker/ICD damage
    • arrhythmia
    • death

Non-Cardiovascular

Device MR Category Comments
Nerve stimulators MR Unsafe
Cochlear implants MR Unsafe
Aneurysm clips Ferromagnetic: MR Unsafe; Non/weakly-ferromagnetic: MR Safe Requires specific information about clip material
Dental materials (alloys, wires, splints, and prostheses) MR Safe
Neurosurgical halo pins MR unsafe?
Transdermal patches If contain aluminum or other metals (in non-adhesive backing): MR Unsafe (remove before MR) Examples: certain clonidine, nicotine, scopolamine, testosterone, or fentanyl patches
Unstable patient MR Conditional Probably should avoid unless an urgent clinical indication without acceptable alternative

Other

  • Pregnancy: Unknown (if any, probably low)
    • Gadolinium-based contrast not recommended unless benefit justifies risk (crosses the placenta)
  • Claustrophobia
  • Agitated
  • Very Obese (depending on system)

MR (Gadolinium-Based) Contrast[2]

Background

  • Unlike iodinated contrast, MR contrast has few side effects and rarely cause anaphylaxis
  • It does cross the placenta

Specific Groups

  • Pregnancy (see above)
    • Gadolinium-based contrast not recommended unless benefit justifies risk
  • Moderate to severe chronic kidney disease:
    • Contrast nephropathy can occur (MR Unsafe)
  • Dialysis and hepatorenal patients in the perioperative liver transplant period
    • Associated nephrogenic systemic fibrosis (MR Unsafe)

Key

  • MR Safe: Generally safe
  • MR Conditional: Weigh risk/benefit (relative contraindication)
  • MR Unsafe: Generally contraindicated (absolute contraindication)

See Also

Source

<references>

  1. 25.Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 2007; 116:2878.
  2. 25.Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 2007; 116:2878.